Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Adv Sci (Weinh) ; 11(2): e2301873, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38009788

RESUMEN

Small voids in the absorber layer of thin-film solar cells are generally suspected to impair photovoltaic performance. They have been studied on Cu(In,Ga)Se2 cells with conventional laboratory techniques, albeit limited to surface characterization and often affected by sample-preparation artifacts. Here, synchrotron imaging is performed on a fully operational as-deposited solar cell containing a few tens of voids. By measuring operando current and X-ray excited optical luminescence, the local electrical and optical performance in the proximity of the voids are estimated, and via ptychographic tomography, the depth in the absorber of the voids is quantified. Besides, the complex network of material-deficit structures between the absorber and the top electrode is highlighted. Despite certain local impairments, the massive presence of voids in the absorber suggests they only have a limited detrimental impact on performance.

2.
Sci Rep ; 13(1): 318, 2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36609430

RESUMEN

Being able to observe the formation of multi-material nanostructures in situ, simultaneously from a morphological and crystallographic perspective, is a challenging task. Yet, this is essential for the fabrication of nanomaterials with well-controlled composition exposing the most active crystallographic surfaces, as required for highly active catalysts in energy applications. To demonstrate how X-ray ptychography can be combined with scanning nanoprobe diffraction to realize multimodal imaging, we study growing Cu2O nanocubes and their transformation into Au nanocages. During the growth of nanocubes at a temperature of 138 °C, we measure the crystal structure of an individual nanoparticle and determine the presence of (100) crystallographic facets at its surface. We subsequently visualize the transformation of Cu2O into Au nanocages by galvanic replacement. The nanocubes interior homogeneously dissolves while smaller Au particles grow on their surface and later coalesce to form porous nanocages. We finally determine the amount of radiation damage making use of the quantitative phase images. We find that both the total surface dose as well as the dose rate imparted by the X-ray beam trigger additional deposition of Au onto the nanocages. Our multimodal approach can benefit in-solution imaging of multi-material nanostructures in many related fields.

3.
Nat Commun ; 13(1): 4971, 2022 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-36038564

RESUMEN

Understanding morphological changes of nanoparticles in solution is essential to tailor the functionality of devices used in energy generation and storage. However, we lack experimental methods that can visualize these processes in solution, or in electrolyte, and provide three-dimensional information. Here, we show how X-ray ptychography enables in situ nano-imaging of the formation and hollowing of nanoparticles in solution at 155 °C. We simultaneously image the growth of about 100 nanocubes with a spatial resolution of 66 nm. The quantitative phase images give access to the third dimension, allowing to additionally study particle thickness. We reveal that the substrate hinders their out-of-plane growth, thus the nanocubes are in fact nanocuboids. Moreover, we observe that the reduction of Cu2O to Cu triggers the hollowing of the nanocuboids. We critically assess the interaction of X-rays with the liquid sample. Our method enables detailed in-solution imaging for a wide range of reaction conditions.

4.
Sci Rep ; 12(1): 6203, 2022 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-35418587

RESUMEN

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

5.
J Synchrotron Radiat ; 28(Pt 5): 1518-1527, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475299

RESUMEN

Many processes and materials in heterogeneous catalysis undergo dynamic structural changes depending on their chemical environment. Monitoring such dynamic changes can be challenging using conventional spectroscopic characterization tools, due to the high time resolution required. Here, a high-resolution 2D X-ray camera operating at 50 Hz full-frame rate was synchronized with a QEXAFS monochromator, enabling rapid spectro-microscopic imaging with chemical contrast over individual pixels. This was used to monitor chemical gradients within a model Pt/Al2O3 catalyst during catalytic partial oxidation of methane to synthesis gas. The transition from methane combustion (partly oxidized Pt) to combustion-reforming and partial oxidation (fully reduced Pt) was observed by a characteristic reduction front, which progressed from the end of the catalyst bed towards its beginning on the second time scale. The full-field QEXAFS imaging method applied here allows acquisition of entire XANES spectra `on the fly' in a rapid and spatially resolved manner. The combination of high spatial and temporal resolution with spectroscopic data offers new opportunities for observing dynamic processes in catalysts and other functional materials at work. The methodology is flexible and can be applied at beamlines equipped with a QEXAFS or other fast-scanning monochromators and a suitable sample environment for gas phase analytics to allow for catalytic studies at the same time.

6.
Opt Express ; 29(14): 22345-22365, 2021 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-34266001

RESUMEN

Ptychography, a scanning coherent diffraction imaging method, can produce a high-resolution reconstruction of a sample and, at the same time, of the illuminating beam. The emergence of vacuum ultraviolet and X-ray free electron lasers (FELs) has brought sources with unprecedented characteristics that enable X-ray ptychography with highly intense and ultra-fast short-wavelength pulses. However, the shot-to-shot pulse fluctuations typical for FEL pulses and particularly the partial spatial coherence of self-amplified spontaneous emission (SASE) FELs lead to numerical complexities in the ptychographic algorithms and ultimately restrict the application of ptychography at FELs. We present a general adaptive forward model for ptychography based on automatic differentiation, which is able to perform reconstructions even under these conditions. We applied this model to the first ptychography experiment at FLASH, the Free electron LASer in Hamburg, and obtained a high-resolution reconstruction of the sample as well as the complex wavefronts of individual FLASH pulses together with their coherence properties. This is not possible with more common ptychography algorithms.

7.
Opt Express ; 29(9): 14025-14032, 2021 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-33985128

RESUMEN

We report on the manufacturing and testing of the first nanofocusing refractive lenses made of single-crystal silicon carbide. We introduce the fabrication process based on lithography, followed by deep isotropic etching. The lenses were characterized at the energy of 12 keV at the beamline P06 of the synchrotron radiation source PETRA III. A focal spot of 186 nm×275 nm has been achieved with a lens working distance of 29 mm.

8.
J Synchrotron Radiat ; 28(Pt 3): 1030, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33950011

RESUMEN

A correction in the paper by Seiboth et al. [(2018). J. Synchrotron Rad. 25, 108-115] is made.

10.
Sci Rep ; 11(1): 1500, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33452343

RESUMEN

Ptychographic X-ray microscopy is an ideal tool to observe chemical processes under in situ conditions. Chemical reactors, however, are often thicker than the depth of field, limiting the lateral spatial resolution in projection images. To overcome this limit and reach higher lateral spatial resolution, wave propagation within the sample environment has to be taken into account. Here, we demonstrate this effect recording a ptychographic projection of copper(I) oxide nanocubes grown on two sides of a polyimide foil. Reconstructing the nanocubes using the conventional ptychographic model shows the limitation in the achieved resolution due to the thickness of the foil. Whereas, utilizing a multi-slice approach unambiguously separates two sharper reconstructions of nanocubes on both sides of the foil. Moreover, we illustrate how ptychographic multi-slice reconstructions are crucial for high-quality imaging of chemical processes by ex situ studying copper(I) oxide nanocubes grown on the walls of a liquid cell.

11.
Materials (Basel) ; 14(1)2021 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-33466442

RESUMEN

Inhomogeneities and defects often limit the overall performance of thin-film solar cells. Therefore, sophisticated microscopy approaches are sought to characterize performance and defects at the nanoscale. Here, we demonstrate, for the first time, the simultaneous assessment of composition, structure, and performance in four-fold multi-modality. Using scanning X-ray microscopy of a Cu(In,Ga)Se2 (CIGS) solar cell, we measured the elemental distribution of the key absorber elements, the electrical and optical response, and the phase shift of the coherent X-rays with nanoscale resolution. We found structural features in the absorber layer-interpreted as voids-that correlate with poor electrical performance and point towards defects that limit the overall solar cell efficiency.

12.
J Appl Crystallogr ; 53(Pt 4): 957-971, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32788903

RESUMEN

Ptychographic X-ray imaging at the highest spatial resolution requires an optimal experimental environment, providing a high coherent flux, excellent mechanical stability and a low background in the measured data. This requires, for example, a stable performance of all optical components along the entire beam path, high temperature stability, a robust sample and optics tracking system, and a scatter-free environment. This contribution summarizes the efforts along these lines to transform the nanoprobe station on beamline P06 (PETRA III) into the ptychographic nano-analytical microscope (PtyNAMi).

13.
J Synchrotron Radiat ; 27(Pt 1): 185-198, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31868751

RESUMEN

Friedreich's ataxia (FRDA) is a neurodegenerative disease characterized by an increase in intracytoplasmic iron concentration. Here the nanoscale iron distribution within single fibroblasts from FRDA patients was investigated using synchrotron-radiation-based nanoscopic X-ray fluorescence and X-ray in-line holography at the ID16A nano-imaging beamline of the ESRF. This unique probe was deployed to uncover the iron cellular two-dimensional architecture of freeze-dried FRDA fibroblasts. An unsurpassed absolute detection capability of 180 iron atoms within a 30 nm × 50 nm nanoscopic X-ray beam footprint was obtained using state-of-the-art X-ray focusing optics and a large-solid-angle detection system. Various micrometre-sized iron-rich organelles could be revealed for the first time, tentatively identified as endoplasmic reticulum, mitochondria and lysosomes. Also a multitude of nanoscopic iron hot-spots were observed in the cytosol, interpreted as chaperoned iron within the fibroblast's labile iron pool. These observations enable new hypotheses on the storage and trafficking of iron in the cell and ultimately to a better understanding of iron-storage diseases such as Friedreich's ataxia.


Asunto(s)
Fibroblastos/química , Ataxia de Friedreich/patología , Holografía/métodos , Hierro/análisis , Análisis de la Célula Individual/métodos , Espectrometría por Rayos X/métodos , Carbono , Citoplasma/química , Fibroblastos/ultraestructura , Liofilización , Humanos , Nanoestructuras , Orgánulos/química , Orgánulos/ultraestructura , Análisis de la Célula Individual/instrumentación , Sincrotrones , Fijación del Tejido/métodos
14.
Opt Lett ; 44(18): 4622-4625, 2019 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-31517948

RESUMEN

In this Letter, we report on the creation of hard x-ray beams carrying orbital angular momentum of topological charge -ℏ and -3ℏ at a photon energy of 8.2 keV via spiral phase plates made out of fused silica by ultrashort-pulsed laser ablation. The phase plates feature a smooth phase ramp with a 0.5 µm nominal step height and a surface roughness of 0.5 µm. The measured vortex beams show submicrometer-sized donut rings and agree well with numerical modeling. Fused silica phase plates are potentially suited to manipulate the electromagnetic field in highly intense x-ray beams at x-ray free-electron laser sources.

15.
J Synchrotron Radiat ; 26(Pt 5): 1769-1781, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31490169

RESUMEN

Two in situ `nanoreactors' for high-resolution imaging of catalysts have been designed and applied at the hard X-ray nanoprobe endstation at beamline P06 of the PETRA III synchrotron radiation source. The reactors house samples supported on commercial MEMS chips, and were applied for complementary hard X-ray ptychography (23 nm spatial resolution) and transmission electron microscopy, with additional X-ray fluorescence measurements. The reactors allow pressures of 100 kPa and temperatures of up to 1573 K, offering a wide range of conditions relevant for catalysis. Ptychographic tomography was demonstrated at limited tilting angles of at least ±35° within the reactors and ±65° on the naked sample holders. Two case studies were selected to demonstrate the functionality of the reactors: (i) annealing of hierarchical nanoporous gold up to 923 K under inert He environment and (ii) acquisition of a ptychographic projection series at ±35° of a hierarchically structured macroporous zeolite sample under ambient conditions. The reactors are shown to be a flexible and modular platform for in situ studies in catalysis and materials science which may be adapted for a range of sample and experiment types, opening new characterization pathways in correlative multimodal in situ analysis of functional materials at work. The cells will presently be made available for all interested users of beamline P06 at PETRA III.


Asunto(s)
Catálisis , Ciencia de los Materiales/instrumentación , Microscopía Electrónica , Electrones , Diseño de Equipo , Oro/química , Sincrotrones , Temperatura , Rayos X , Zeolitas/química
16.
J Synchrotron Radiat ; 25(Pt 1): 108-115, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-29271759

RESUMEN

Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with \bar{\sigma} = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without prior lens characterization but simply based on the derived lens deformation. The performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...